High Limit Aquastat, 100-200-Degree (F) range, Manual Reset, L4006E1125
Description: High Limit; Manual Reset Aquastat Controller with 100 F to 200 F operating temperature Application : High Limit; Manual Reset Insulation Depth (in.): 3 in. Insulation Depth (mm): 76 mm Bulb Size (in.) : 3/8 in. x 2 7/8 in. copper Bulb Size (mm) : 10 mm x 73 mm copper Switching Action : SPST, contacts break on temperature rise. Operating Temperature Range (F) : 100 F to 200 F Operating Temperature Range (C): 38 C to 93 C Electrical Ratings (millivolt): 0.25 A @ 0.25 to 12 Vdc Electrical Ratings (AFL): 8A @ 120 Vac Electrical Ratings (AFL): 1.3A @ 240 Vac Electrical Ratings (ALR): 48A @ 120 Vac Electrical Ratings (ALR): 30.6A @ 240 Vac Differential Temperature (F): Manual Reset Differential Temperature (C): Manual Reset Maximum Ambient Temperature (F): 150 F Maximum Ambient Temperature (C): 66 C Case Dimensions (in.): 5 5/8 in. high x 2 in. wide x 2 1/8 in. deep Case Dimensions (mm) : 143 mm high x 51 mm wide x 54 mm deep Mounting: Horizontal or Vertical Approvals, Underwriters Laboratories Inc UL Component Recognized: File No. MP466, Vol. 6, Sec.1, Guide No. MBPR2 Approvals, Canadian Standards Association Certified: File No. LR95329-1 Approvals, American Gas Association IAS AGA Certified
Your Price
Contract Pricing
Product Overview
Description: High Limit; Manual Reset Aquastat Controller with 100 F to 200 F operating temperature Application : High Limit; Manual Reset Insulation Depth (in.): 3 in. Insulation Depth (mm): 76 mm Bulb Size (in.) : 3/8 in. x 2 7/8 in. copper Bulb Size (mm) : 10 mm x 73 mm copper Switching Action : SPST, contacts break on temperature rise. Operating Temperature Range (F) : 100 F to 200 F Operating Temperature Range (C): 38 C to 93 C Electrical Ratings (millivolt): 0.25 A @ 0.25 to 12 Vdc Electrical Ratings (AFL): 8A @ 120 Vac Electrical Ratings (AFL): 1.3A @ 240 Vac Electrical Ratings (ALR): 48A @ 120 Vac Electrical Ratings (ALR): 30.6A @ 240 Vac Differential Temperature (F): Manual Reset Differential Temperature (C): Manual Reset Maximum Ambient Temperature (F): 150 F Maximum Ambient Temperature (C): 66 C Case Dimensions (in.): 5 5/8 in. high x 2 in. wide x 2 1/8 in. deep Case Dimensions (mm) : 143 mm high x 51 mm wide x 54 mm deep Mounting: Horizontal or Vertical Approvals, Underwriters Laboratories Inc UL Component Recognized: File No. MP466, Vol. 6, Sec.1, Guide No. MBPR2 Approvals, Canadian Standards Association Certified: File No. LR95329-1 Approvals, American Gas Association IAS AGA Certified