Product Details

Review product information, specifications, and procurement details.

High Limit Immersion Aquastat, 100-200-Degree (F) Range, L4080B1352
● In Stock

High Limit Immersion Aquastat, 100-200-Degree (F) Range, L4080B1352

Note: This product does not come with a well. Overview Immersion type controllers for hydronic heating systems that turn off the burner whenever the boiler water temperature rises to the setpoint. Vertical mounting. Features High Limit Aquastat Controller has adjustable set point. Models available for use with immersion wells or for direct immersion if faster response is needed. A factory-set stop is available on L4080 to prevent setting the control at too high a temperature. Models available with second limit switch to shut off all gas to the burner. Liquid fill in sensing element expands as the boiler temperature rises. At the set point temperature, a diaphragm-actuated snap switch breaks the power supply to the burner primary control. Product Specifications Application: Immersion type controllers for hydronic heating systems that turn off the burner whenever the boiler water temperature rises to the set point. Insertion depth: 3 in. Temperature Range (F): Maximum - 40 F above setpoint or 265 F, which ever is lower. Includes: Siphon Loop Mounting: Mount using 1/4 in. NPT female threads or surface mount through base of case Electrical Ratings (Millivolt) 0.25 A @ 0.25 to 12 Vdc At Full Load - 8A @ 120 Vac , 4A @ 240 Vac At Locked Rotor - 48A @ 120 Vac , 24A @ 240 Vac Operating Temperature Range (F): 100 F to 200 F Differential Temperature (F): 8 F Switching Action: Breaks contact on temperature rise to set point. Insulation Depth (in.): 1 1/2 in. to 3 in.

Hubzone SKU L4080B1352
Manufacturer Resideo
Manufacturer Part Number L4080B1352
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

Note: This product does not come with a well. Overview Immersion type controllers for hydronic heating systems that turn off the burner whenever the boiler water temperature rises to the setpoint. Vertical mounting. Features High Limit Aquastat Controller has adjustable set point. Models available for use with immersion wells or for direct immersion if faster response is needed. A factory-set stop is available on L4080 to prevent setting the control at too high a temperature. Models available with second limit switch to shut off all gas to the burner. Liquid fill in sensing element expands as the boiler temperature rises. At the set point temperature, a diaphragm-actuated snap switch breaks the power supply to the burner primary control. Product Specifications Application: Immersion type controllers for hydronic heating systems that turn off the burner whenever the boiler water temperature rises to the set point. Insertion depth: 3 in. Temperature Range (F): Maximum - 40 F above setpoint or 265 F, which ever is lower. Includes: Siphon Loop Mounting: Mount using 1/4 in. NPT female threads or surface mount through base of case Electrical Ratings (Millivolt) 0.25 A @ 0.25 to 12 Vdc At Full Load - 8A @ 120 Vac , 4A @ 240 Vac At Locked Rotor - 48A @ 120 Vac , 24A @ 240 Vac Operating Temperature Range (F): 100 F to 200 F Differential Temperature (F): 8 F Switching Action: Breaks contact on temperature rise to set point. Insulation Depth (in.): 1 1/2 in. to 3 in.

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents