Product Details

Review product information, specifications, and procurement details.

Universal Reset Control - Two Mixing, Two Stage Boiler, DHW & Setpoint
● In Stock

Universal Reset Control - Two Mixing, Two Stage Boiler, DHW & Setpoint

Control Description: The Universal Reset Control 374 is a microprocessor-based control capable of providing a reset boiler supply temperature and two reset mixed supply temperatures based on outdoor air temperature. For mixing devices, the 374 can use either two variable speed injection pumps or two floating action mixing valves. The 374 is also capable of controlling an indirect Domestic Hot Water (DHW) tank and / or a setpoint load. The control is also capable of controlling up to two on / off boiler stages. Individual zone temperature control can be achieved by using a conventional thermostat system. Features:. 2 X variable speed pump outputs or 2 X floating action mixing outputs 3 Outdoor Temperature Reset controlled water temperatures Advanced settings to fine-tune building requirements Automatic Boiler Differentia Boiler Load Reset Control up to 2 On/Off boilers DHW Priority (optional) DHW pump or valve operation Equal Run Time Rotation Exercising Outdoor Temperature Reset Powered boiler system and mixing system pump outputs Quick setup for easy installation Test sequence to ensure proper operation User comfort adjustment to increase or decrease building space temperature Warm Weather Shut Down CSA C US certified (approved to applicable UL standards)

Hubzone SKU 374
Manufacturer Tekmar
Manufacturer Part Number 374
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

Control Description: The Universal Reset Control 374 is a microprocessor-based control capable of providing a reset boiler supply temperature and two reset mixed supply temperatures based on outdoor air temperature. For mixing devices, the 374 can use either two variable speed injection pumps or two floating action mixing valves. The 374 is also capable of controlling an indirect Domestic Hot Water (DHW) tank and / or a setpoint load. The control is also capable of controlling up to two on / off boiler stages. Individual zone temperature control can be achieved by using a conventional thermostat system. Features:. 2 X variable speed pump outputs or 2 X floating action mixing outputs 3 Outdoor Temperature Reset controlled water temperatures Advanced settings to fine-tune building requirements Automatic Boiler Differentia Boiler Load Reset Control up to 2 On/Off boilers DHW Priority (optional) DHW pump or valve operation Equal Run Time Rotation Exercising Outdoor Temperature Reset Powered boiler system and mixing system pump outputs Quick setup for easy installation Test sequence to ensure proper operation User comfort adjustment to increase or decrease building space temperature Warm Weather Shut Down CSA C US certified (approved to applicable UL standards)

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents