Product Details

Review product information, specifications, and procurement details.

Universal Reset Module - Four tN4, Two Boiler, DHW & Setpoint
● In Stock

Universal Reset Module - Four tN4, Two Boiler, DHW & Setpoint

Control Description The Universal Reset Module 423 provides outdoor reset to a hydronic heating system in order to maximize comfort and efficiency. The 423 can operate two on / off boilers or two modulating boilers. The 423 can override the outdoor reset water temperature to provide Domestic Hot Water or Setpoint operations. The 423 can operate four outdoor reset water temperatures, up to three of these water temperatures can be mixing water temperatures. To operate a mixing device, a Mixing Expansion Module must be connected to the 423 for each mixing water temperature. Control Microprocessor PID control; This is not a safety (limit) control Packaged Weight 1.9 lb. (1638 g) Dimensions 3-5/8" H x 5-3/8" W x 9/16" D (92 x 137 x 14 mm) Approvals CSA C US, CSA/UL 61010-1, meets Class B: ICES and FCC Part 15 Ambient Conditions Indoor use only, 32 to 122¼F (0 to 50¼C).   RH equal to or less than 92% to 104¼F (40¼C), down to 50% above 104¼F (40¼C)   Altitude Power Supply Provided by interconnected Zone Manager DHW Pump Relay 115 V (ac) 5 A 1/4 hp, pilot duty 240 VA Primary Pump Relay 115 V (ac) 5 A 1/4 hp, pilot duty 240 VA Combined Load 10 A Maximum (for DHW and Primary Pump) DHW Valve Output 24 V (ac) 8 VA Maximum Modulation Output 0-10 V Minimum 2500 Ω Boiler Relay 115 V (ac) 5 A 1/4 hp, pilot duty 240 VA Demands 20-260 V (ac) / 0.1 VA @ 24 V Sensors NTC thermistor, 10 kΩ @ 77¼F (25¼C ¼0.2¼C) +=3892 Included Outdoor Sensor 070 and Universal Sensor 071

Hubzone SKU 423
Manufacturer Tekmar
Manufacturer Part Number 423
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

Control Description The Universal Reset Module 423 provides outdoor reset to a hydronic heating system in order to maximize comfort and efficiency. The 423 can operate two on / off boilers or two modulating boilers. The 423 can override the outdoor reset water temperature to provide Domestic Hot Water or Setpoint operations. The 423 can operate four outdoor reset water temperatures, up to three of these water temperatures can be mixing water temperatures. To operate a mixing device, a Mixing Expansion Module must be connected to the 423 for each mixing water temperature. Control Microprocessor PID control; This is not a safety (limit) control Packaged Weight 1.9 lb. (1638 g) Dimensions 3-5/8" H x 5-3/8" W x 9/16" D (92 x 137 x 14 mm) Approvals CSA C US, CSA/UL 61010-1, meets Class B: ICES and FCC Part 15 Ambient Conditions Indoor use only, 32 to 122¼F (0 to 50¼C).   RH equal to or less than 92% to 104¼F (40¼C), down to 50% above 104¼F (40¼C)   Altitude Power Supply Provided by interconnected Zone Manager DHW Pump Relay 115 V (ac) 5 A 1/4 hp, pilot duty 240 VA Primary Pump Relay 115 V (ac) 5 A 1/4 hp, pilot duty 240 VA Combined Load 10 A Maximum (for DHW and Primary Pump) DHW Valve Output 24 V (ac) 8 VA Maximum Modulation Output 0-10 V Minimum 2500 Ω Boiler Relay 115 V (ac) 5 A 1/4 hp, pilot duty 240 VA Demands 20-260 V (ac) / 0.1 VA @ 24 V Sensors NTC thermistor, 10 kΩ @ 77¼F (25¼C ¼0.2¼C) +=3892 Included Outdoor Sensor 070 and Universal Sensor 071

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents