Product Details
Review product information, specifications, and procurement details.
Pneumatic Thermostat Direct Acting Heating (Day/Night Setpoint), TP971A2003
Pneumatic thermostat with night setback used to provide proportional control of pneumatic valves and damper actuators in heating and air conditioning systems. Replacement kits are available for Johnson, Powers, Robertshaw, Barber-Colman, and older Honeywell two-pipe pneumatic thermostats.FeaturesDurable TP970 series thermostat Pilot operated for high capacityDirect Acting (DA) and Reverse Acting (RA) models are availableThree-pipe thermostats are available for unit ventilator applications where the outdoor damper must operate when the thermostat is manually set to day operationAdapter plate in thermostat kits covers existing thermostat watermarkBackplate has molded air connections-no separate fittings neededUniversal Locking cover with satin chrome finish and horizontal, vertical, or blank window options-other covers available Specifications Description: Pneumatic Thermostat Direct Acting HeatingApplication: Wall Thermostat, Day/Night operationRemote Bulb: NoSetpoint: Day/NightAction: Direct Acting Heating, two tempNumber of Pipes: 2Setpoint Temperature Range: Day: 59 F to 90 F, Night: 50 F to 80 FSensor Element: BimetalChangeover Pressure: Day 13 psi, Night 18 psiMaximum Safe Operating Pressure (psi) 25 PSIOperating Temperature Range (F): 100F MaximumThrottling Range (F): 2 F to 10 F (factory set 4 F)Airflow Usage: 0.011 scfm (5.2 mL/s)Dimensions: 3-1/4 in. high x 2 in. wide x 1-5/8 in. deepMounting: wallNote: Order cover separately
Your Price
Contract Pricing
Product Overview
Pneumatic thermostat with night setback used to provide proportional control of pneumatic valves and damper actuators in heating and air conditioning systems. Replacement kits are available for Johnson, Powers, Robertshaw, Barber-Colman, and older Honeywell two-pipe pneumatic thermostats.FeaturesDurable TP970 series thermostat Pilot operated for high capacityDirect Acting (DA) and Reverse Acting (RA) models are availableThree-pipe thermostats are available for unit ventilator applications where the outdoor damper must operate when the thermostat is manually set to day operationAdapter plate in thermostat kits covers existing thermostat watermarkBackplate has molded air connections-no separate fittings neededUniversal Locking cover with satin chrome finish and horizontal, vertical, or blank window options-other covers available Specifications Description: Pneumatic Thermostat Direct Acting HeatingApplication: Wall Thermostat, Day/Night operationRemote Bulb: NoSetpoint: Day/NightAction: Direct Acting Heating, two tempNumber of Pipes: 2Setpoint Temperature Range: Day: 59 F to 90 F, Night: 50 F to 80 FSensor Element: BimetalChangeover Pressure: Day 13 psi, Night 18 psiMaximum Safe Operating Pressure (psi) 25 PSIOperating Temperature Range (F): 100F MaximumThrottling Range (F): 2 F to 10 F (factory set 4 F)Airflow Usage: 0.011 scfm (5.2 mL/s)Dimensions: 3-1/4 in. high x 2 in. wide x 1-5/8 in. deepMounting: wallNote: Order cover separately