Sideshot Oil Vent System, SS1C
● In Stock

Sideshot Oil Vent System, SS1C

This is a mechanical vent system designed and listed for use with natural draft oil heating equipment. It is factory assembled and wired. It automatically vents the flue gases from heating equipment to the outdoors. By combining outside air with high-tech insulation, surrounding combustible materials and the Vent Hood exterior remain at safe temperatures. After each burner cycle the SS1C will continue to operate in post-purge mode to purge the heater and vent of residual flue gases. A factory post-purge time is set at 2 minutes and is adjustable up 16 minutes, see "Pre / Post-purge Settings" on page 5. The SS1C features a safety system consisting of the integral UC1 Universal Control, a Fan Proving Switch and a High Limit temperature control. These devices monitor the SS1C's performance and will interrupt the main burner if a venting malfunction is detected. Specifications: * Motor: 115/1/60, 3300 RPM, 212 watts, 2.28 FLA * Fan Proving Switch: Non-adjustable, N/O with a set point of -.04" W.C. * High Limit: Manual reset, N/C contacts, open at 79oC (175oF) + 8oC (15oF) * Pre-Purge: Options (0, 15, 30, 60 seconds) * Post-Purge: Factory set at 2 minutes, Options (0, 30 seconds or 1, 2, 4, 8, 16 minutes).

Hubzone SKU SS1C
Manufacturer Tjernlund
Manufacturer Part Number SS1C
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

This is a mechanical vent system designed and listed for use with natural draft oil heating equipment. It is factory assembled and wired. It automatically vents the flue gases from heating equipment to the outdoors. By combining outside air with high-tech insulation, surrounding combustible materials and the Vent Hood exterior remain at safe temperatures. After each burner cycle the SS1C will continue to operate in post-purge mode to purge the heater and vent of residual flue gases. A factory post-purge time is set at 2 minutes and is adjustable up 16 minutes, see "Pre / Post-purge Settings" on page 5. The SS1C features a safety system consisting of the integral UC1 Universal Control, a Fan Proving Switch and a High Limit temperature control. These devices monitor the SS1C's performance and will interrupt the main burner if a venting malfunction is detected. Specifications: * Motor: 115/1/60, 3300 RPM, 212 watts, 2.28 FLA * Fan Proving Switch: Non-adjustable, N/O with a set point of -.04" W.C. * High Limit: Manual reset, N/C contacts, open at 79oC (175oF) + 8oC (15oF) * Pre-Purge: Options (0, 15, 30, 60 seconds) * Post-Purge: Factory set at 2 minutes, Options (0, 30 seconds or 1, 2, 4, 8, 16 minutes).

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents