Product Details

Review product information, specifications, and procurement details.

Universal Hot Surface Ignition Integrated Furnace Control, S9200U1000
● In Stock

Universal Hot Surface Ignition Integrated Furnace Control, S9200U1000

Product Overview The S9200U1000 Universal Integrated Furnace Control can be used with conventional thermostats as well as the EnviraCOM enabled VisionPRO IAQ and FocusPRO. It is intended for residential natural or liquid propane fueled furnaces only. The S9200U1000 EnviraCOM communications capability allows its use in twinning applications and enables communication with local and remote diagnostic devices such as the QuickLook hand held device (QuickLook 72), EnviraLINK® web-based application and the W8735D Telephone Access Universal Hot Surface Ignition Integrated Furnace Control. Controls a standard induction-type circulating fan motor. FeaturesMain burner ignition using a 120V hot surface igniter. Flame rectification circuit to monitor flame presence. Monitoring of system pressure switch, high temperature limit, and rollout functions. Appliance operation/safety requirements controlled via microprocessor. Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM thermostat. LED system status, performance and diagnostic indication. Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances. Twinning capability EnviraCOM communication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control. Specifications Description: Universal single stage heating & coolingLine Voltage: 120Vac (97-132 Vac)Low Voltage: 24V (18-30Vac)Frequency: 60 HzOperating Temperature (F): -40 F to +175 FOperating Temperature (C): -40 C to +79 COperating Humidity Range (% RH): 0% to 95% non-condensingIgniter Current: 1.0A resistive @ 95Vac outputThermostat Anticipator Setting: (Stage 1 only) 100mAPrePurge: 30 secondsHSI Warmup Time: 17/27 or 30/30 secondsTrial For Ignition: 4, 6, or 8 secondsPostPurge: 15 secondsInterpurge: 60 secondsIgnition Trials: Three, two tries if flame is not sensedFlame Failure Response Time: 2 Seconds max @ 1µANumber of LEDs: 3Heat On Fan Delay: 30 or 60 secondsHeat Off Fan Delay: 60, 90, 120, or 180 SecondsCool Fan On Delay: 5 secondsCool Fan Off Delay: 0 or 60 secondsGas Control Used With: Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.Cooling Contactor Used With: Any 24Vac contactor rated at 1.0A or lessInduced Draft Blower Load: 2.2FLA / 25LRA max @120VacCirculator Load: 14.5FLA / 25LRA max @120VacType of Fan Used With: Standard Induction-Type Circulating Fan

Hubzone SKU S9200U1000
Manufacturer Resideo
Manufacturer Part Number S9200U1000
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

Product Overview The S9200U1000 Universal Integrated Furnace Control can be used with conventional thermostats as well as the EnviraCOM enabled VisionPRO IAQ and FocusPRO. It is intended for residential natural or liquid propane fueled furnaces only. The S9200U1000 EnviraCOM communications capability allows its use in twinning applications and enables communication with local and remote diagnostic devices such as the QuickLook hand held device (QuickLook 72), EnviraLINK® web-based application and the W8735D Telephone Access Universal Hot Surface Ignition Integrated Furnace Control. Controls a standard induction-type circulating fan motor. FeaturesMain burner ignition using a 120V hot surface igniter. Flame rectification circuit to monitor flame presence. Monitoring of system pressure switch, high temperature limit, and rollout functions. Appliance operation/safety requirements controlled via microprocessor. Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM thermostat. LED system status, performance and diagnostic indication. Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances. Twinning capability EnviraCOM communication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control. Specifications Description: Universal single stage heating & coolingLine Voltage: 120Vac (97-132 Vac)Low Voltage: 24V (18-30Vac)Frequency: 60 HzOperating Temperature (F): -40 F to +175 FOperating Temperature (C): -40 C to +79 COperating Humidity Range (% RH): 0% to 95% non-condensingIgniter Current: 1.0A resistive @ 95Vac outputThermostat Anticipator Setting: (Stage 1 only) 100mAPrePurge: 30 secondsHSI Warmup Time: 17/27 or 30/30 secondsTrial For Ignition: 4, 6, or 8 secondsPostPurge: 15 secondsInterpurge: 60 secondsIgnition Trials: Three, two tries if flame is not sensedFlame Failure Response Time: 2 Seconds max @ 1µANumber of LEDs: 3Heat On Fan Delay: 30 or 60 secondsHeat Off Fan Delay: 60, 90, 120, or 180 SecondsCool Fan On Delay: 5 secondsCool Fan Off Delay: 0 or 60 secondsGas Control Used With: Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.Cooling Contactor Used With: Any 24Vac contactor rated at 1.0A or lessInduced Draft Blower Load: 2.2FLA / 25LRA max @120VacCirculator Load: 14.5FLA / 25LRA max @120VacType of Fan Used With: Standard Induction-Type Circulating Fan

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents