Product Details
Review product information, specifications, and procurement details.
Protectorelay Oil Burner Control with 45 seconds Lock Out Timing, R8184M1051
Provides automatic, nonrecycling control of an intermittent ignition oil burner system. Specifications Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat. Solid state flame sensing circuit. LED on terminal strip indicates system lockout. Remote lockout indication available on some models. Enclosed safety switch with external reset button. Manual trip lever opens safety switch for system maintenance. Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing. C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required. Features Description: Protectorelay Oil Burner Control with 45 seconds lock out timingIgnition Type: IntermittentTiming, Safety Switch: 45 sec.Mounting Bracket: Mounts on standard 4 x 4 in. junction boxElectrical Ratings (Full Load): 7.4 A @ 120 Vac; 3.7 a @ 240 VacElectrical Ratings (Locked Rotor): 44.4 A @ 120 Vac; 22.2 A @ 240 VacAlarm Load Ratings (Pilot Duty): 75 VA @ 120/240 Vac, 50-60 Hz; 25 VA @ 24V, 50-60 HzAlarm Load Ratings (resistive): 1.5 A @ 120/240V, 50-60Hz; 3 A @ 24 V, 50-60 HzDimensions: 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deepTemperature Range: -40 F to +130
Your Price
Contract Pricing
Product Overview
Provides automatic, nonrecycling control of an intermittent ignition oil burner system. Specifications Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat. Solid state flame sensing circuit. LED on terminal strip indicates system lockout. Remote lockout indication available on some models. Enclosed safety switch with external reset button. Manual trip lever opens safety switch for system maintenance. Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing. C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required. Features Description: Protectorelay Oil Burner Control with 45 seconds lock out timingIgnition Type: IntermittentTiming, Safety Switch: 45 sec.Mounting Bracket: Mounts on standard 4 x 4 in. junction boxElectrical Ratings (Full Load): 7.4 A @ 120 Vac; 3.7 a @ 240 VacElectrical Ratings (Locked Rotor): 44.4 A @ 120 Vac; 22.2 A @ 240 VacAlarm Load Ratings (Pilot Duty): 75 VA @ 120/240 Vac, 50-60 Hz; 25 VA @ 24V, 50-60 HzAlarm Load Ratings (resistive): 1.5 A @ 120/240V, 50-60Hz; 3 A @ 24 V, 50-60 HzDimensions: 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deepTemperature Range: -40 F to +130