3 Phase SPDT Voltage Monitor (200-480V)
● In Stock

3 Phase SPDT Voltage Monitor (200-480V)

The PLMU11 continuously measures the voltage of each of the three phases to provide protection for 3-phase motors and sensitive loads. Its microcontroller senses under and overvoltage, voltage unbalance, phase loss, and phase reversal. Protection is provided even when regenerated voltages are present. Universal voltage operation from 200 to 480 VAC and standard base connection allows the PLMU11 to replace hundreds of competitive part numbers. Operation Upon application of power, a 0.6s random start delay begins and the PLMU11 measures the voltage levels and line frequency and selects the voltage range. The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. LED flashes green during trip delay, glows red when output de-energizes. undervoltage, overvoltage, and voltage unbalance must be sensed for continuous trip delay before the relay de-energizes. Reenergization is automatic upon fault correction. The output relay will not energize if a fault condition is sensed as 3-phase input voltage is applied. The LED alternately flashes red/green when phase reversal is sensed. Line voltage is selected with the knob, setting the over and under voltage trip points. Voltage range is automatically selected by the microcontroller. Specifications: Input Voltage (V): 200 to 480VAC Input Tolerance (%): 15% Input Voltage Maximum (V): 552VAC Input Type: 3-phase delta or wye with no connection to neutral Input AC Line Frequency (Hz): 50/60Hz 2Hz; 200-240VAC: 50/60Hz; 340-420VAC: 50Hz; 400-480VAC: 60Hz Input Phase Sequence: ABC Output Type: Energized when voltages are acceptable Output Form: Isolated SPDT Output Load Rating (VA): 10A resistive @ 240VAC; 1/4hp @ 125VAC; 1/3hp @ 250VAC; 277VAC max Random Start Delay: 0.6s Reset Time (ms): Automatic Response Time (ms): Phase loss: 200ms; Phase reversal: 200ms Trip Delay Range: Adjustable from 0.25-30s Trip Delay Tolerance (%): 15% Overvoltage Trip Voltage (%): 109-113% of the adjusted line voltage Overvoltage Reset Voltage (%): -2% of the trip voltage Undervoltage Trip Voltage: 88-92% of the adjusted line voltage Undervoltage Reset Voltage (%): +2% of the trip voltage Voltage Unbalance Trip Point (%): Adjustable from 2-10% Voltage Unbalance Reset (%): Selected unbalance %/Reset %: 2/1.5; 3/2.5; 4/3.5; 5/4.5; 6/5.4; 7/6.3; 8/7.2; 9/8.1; 10/9 Severe Unbalance: 0.25-2s; disabled when the trip delay is less than 2s Phase Loss: 15% unbalance Isolation Voltage (V): 2500V RMS input to output Surge Protection: IEEE C62.41-1991 Level B Type of Detection: Voltage detection with delayed trip and automatic reset Life: Mechanical - 1 x 106; Electrical - 1 x 105 Termination Type: Octal 8-pin plug-in Mounting Method: Plug-in socket rated 600V Operating Temperature: -40° to 60°C (-40°F to 140°F) Storage Temperature (F/C): -40° to 85°C (-40°F to 185°F) Dimensions: 3.03 x 2.39 x 1.78 in. (77.0 x 60.7 x 45.2mm)

Hubzone SKU PLMU11
Manufacturer Littelfuse
Manufacturer Part Number PLMU11
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

The PLMU11 continuously measures the voltage of each of the three phases to provide protection for 3-phase motors and sensitive loads. Its microcontroller senses under and overvoltage, voltage unbalance, phase loss, and phase reversal. Protection is provided even when regenerated voltages are present. Universal voltage operation from 200 to 480 VAC and standard base connection allows the PLMU11 to replace hundreds of competitive part numbers. Operation Upon application of power, a 0.6s random start delay begins and the PLMU11 measures the voltage levels and line frequency and selects the voltage range. The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. LED flashes green during trip delay, glows red when output de-energizes. undervoltage, overvoltage, and voltage unbalance must be sensed for continuous trip delay before the relay de-energizes. Reenergization is automatic upon fault correction. The output relay will not energize if a fault condition is sensed as 3-phase input voltage is applied. The LED alternately flashes red/green when phase reversal is sensed. Line voltage is selected with the knob, setting the over and under voltage trip points. Voltage range is automatically selected by the microcontroller. Specifications: Input Voltage (V): 200 to 480VAC Input Tolerance (%): 15% Input Voltage Maximum (V): 552VAC Input Type: 3-phase delta or wye with no connection to neutral Input AC Line Frequency (Hz): 50/60Hz 2Hz; 200-240VAC: 50/60Hz; 340-420VAC: 50Hz; 400-480VAC: 60Hz Input Phase Sequence: ABC Output Type: Energized when voltages are acceptable Output Form: Isolated SPDT Output Load Rating (VA): 10A resistive @ 240VAC; 1/4hp @ 125VAC; 1/3hp @ 250VAC; 277VAC max Random Start Delay: 0.6s Reset Time (ms): Automatic Response Time (ms): Phase loss: 200ms; Phase reversal: 200ms Trip Delay Range: Adjustable from 0.25-30s Trip Delay Tolerance (%): 15% Overvoltage Trip Voltage (%): 109-113% of the adjusted line voltage Overvoltage Reset Voltage (%): -2% of the trip voltage Undervoltage Trip Voltage: 88-92% of the adjusted line voltage Undervoltage Reset Voltage (%): +2% of the trip voltage Voltage Unbalance Trip Point (%): Adjustable from 2-10% Voltage Unbalance Reset (%): Selected unbalance %/Reset %: 2/1.5; 3/2.5; 4/3.5; 5/4.5; 6/5.4; 7/6.3; 8/7.2; 9/8.1; 10/9 Severe Unbalance: 0.25-2s; disabled when the trip delay is less than 2s Phase Loss: 15% unbalance Isolation Voltage (V): 2500V RMS input to output Surge Protection: IEEE C62.41-1991 Level B Type of Detection: Voltage detection with delayed trip and automatic reset Life: Mechanical - 1 x 106; Electrical - 1 x 105 Termination Type: Octal 8-pin plug-in Mounting Method: Plug-in socket rated 600V Operating Temperature: -40° to 60°C (-40°F to 140°F) Storage Temperature (F/C): -40° to 85°C (-40°F to 185°F) Dimensions: 3.03 x 2.39 x 1.78 in. (77.0 x 60.7 x 45.2mm)

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents