Digi-Zone 2 or 3 Zone Universal Control Panel Kit
New Digi-Zone Panel will control 2 or 3 zones on any HVAC System, up to 3 Stages of heating / 2 stages of cooling. MDP3 Ver. 04 also controls heat pumps and dual fuel as well as many geothermal heat pumps. The digital display is a menu driven screen that guides the installer through the settings for each type of system as well as accurately sets the timings and sensor temperature settings. This panel is expandable up to 103 zones, the most in the industry. To add zones, use the MDPA2 Ver .04 = 2 zone per adder. Specifications • System Type = Gas/Electric or Heat Pump Heat Pump Type = Conventional or Fossil/Dual Fuel Outdoor Balance Point (OBP) Adjustable – 5°F -53°F Thermostat Type – H/C or HP HP Stat RV – O or B Number of Zones – Adjustable 2 to 103 Fan On In Heat – On or Off Fan On In Purge – On or Off Emergency Heat – On or Off Minimum Compressor On Timer – On (2 mins) or Off Staging – Adjustable Timer, # of zones calling or supply air temperature (stage optimization) Changeover Timer = Adjustable 10-30 Minutes Leaving Air Sensor – Capacity protection to shut off HVAC Centra-Zone™ - Zone 1 Master Changeover Disabled or Enabled DS-BK = Switch to low speed based on percentage of zones calling. Test – Enabled or Disabled
Your Price
Contract Pricing
Product Overview
New Digi-Zone Panel will control 2 or 3 zones on any HVAC System, up to 3 Stages of heating / 2 stages of cooling. MDP3 Ver. 04 also controls heat pumps and dual fuel as well as many geothermal heat pumps. The digital display is a menu driven screen that guides the installer through the settings for each type of system as well as accurately sets the timings and sensor temperature settings. This panel is expandable up to 103 zones, the most in the industry. To add zones, use the MDPA2 Ver .04 = 2 zone per adder. Specifications • System Type = Gas/Electric or Heat Pump Heat Pump Type = Conventional or Fossil/Dual Fuel Outdoor Balance Point (OBP) Adjustable – 5°F -53°F Thermostat Type – H/C or HP HP Stat RV – O or B Number of Zones – Adjustable 2 to 103 Fan On In Heat – On or Off Fan On In Purge – On or Off Emergency Heat – On or Off Minimum Compressor On Timer – On (2 mins) or Off Staging – Adjustable Timer, # of zones calling or supply air temperature (stage optimization) Changeover Timer = Adjustable 10-30 Minutes Leaving Air Sensor – Capacity protection to shut off HVAC Centra-Zone™ - Zone 1 Master Changeover Disabled or Enabled DS-BK = Switch to low speed based on percentage of zones calling. Test – Enabled or Disabled