Product Details

Review product information, specifications, and procurement details.

LT17A, Classic Style Digital Multimeter w/ Temperature
● In Stock

LT17A, Classic Style Digital Multimeter w/ Temperature

What's Included: Classic Style Clamp Meter with Temperature - LT17A Deluxe Silicone Test Leads - ADLS2 Short Alligator Lead Extensions - ASA2 400A Amp Clamp Accessory - ACH4 Wrap Tab Bead Tip Thermocouple - ATB1 Mail Pouch-Style Instrument Case - ANC5 9V battery (installed) Operator's manual Overview: The LT17A is a manual ranger that covers most of the parameters and ranges you need for most HVAC/R applications. The LT17A meter measures current, resistance, voltage, capacitance, frequency, continuity, and temperature. Test leads store in the meter body and, with the probe tips removed, connect the LT17A to Fieldpiece accessory heads. The body is made out of durable ABS plastic and comes with a bright blue backlight for poorly lit test areas. Get great accuracy using the included k-type thermocouple and an easily accessible temperature calibration pot. The LT17A is a manual ranging DMM that comes with an amp clamp and k-type thermocouple. Use the MIN/MAX function to record highs and lows. The continuity beeper tells you if a circuit is open or closed. Operation of the LT17A is easy. Simply select a range and test. Features and Benefits: Works with Fieldpiece Accessory Heads There is a Fieldpiece accessory head available for just about any job. There are heads to measure temperature, superheat, subcooling, RH%, wet bulb, dew point, vacuum (microns of mercury), manometer (inches of water column), amps AC&DC, high voltage, CO, %CO2, air velocity, and many more. Continuity Indicator If you were doing lab testing, these features would probably drive you crazy. We've heard from more than one HVAC/R veteran that these features really remind you of what you're doing and they've avoided potentially dangerous situations in the field. The Hi-V LED and beeper let you know when you've hooked up to a circuit over 30V. The continuity LED and beeper tells you if a circuit is open or closed. 400AAC Using the detachable test leads and the accessory head amp clamp, read 0-400 amps directly on your meter. Capacitance (MFD) Measure microfarads on motor-run and motor-start capacitors using this range. Disconnect the capacitor from power first. Short the terminals to discharge the capacitor. Disconnect any resistors that might be between the terminals of the capacitor and measure to check for degradation. Microamps DC - Flame Rectification Tests The most common "no heat" call has to do with a malfunctioning flame sensing diode. Simply turn the meter to microamps DC, hook up, and see if the flame sensing rod is functioning properly. Frequency Measure from 10Hz to 40kHz using this range with 1 Hz resolution Silicone Leads with Detachable Probe Tips Because the wire insulation is silicone, the leads stay flexible in cold weather and will not melt if bumped by a soldering iron. When testing electrical circuits with two hands, there is a risk that a careless mistake may complete a circuit through your body and potentially cause death or injury. Use the either probe clip on rubber boot to connect and firmly hold the V lead in place, detach the COM probe tip, connect an alligator lead tip to COM and ground, and perform a one-hand test more easily than most meters on the market. Built-in lead storage makes it easy to keep everything together from job to job. Tilt Stand and Magnetic Hanger Technicians enjoy the magnetic hanger because it keeps the meter out of the way while testing. The LT17A includes the magnet and a tilt stand to give you a choice in the way you want to use it. Bright Blue Backlight Easily read the display in overcast conditions or in dimly lit areas. MAX/MIN hold Record the minimum or maximum reading during a measurement. To exit the MIN/MAX function, hold the button for more than 2 seconds More Features: Volts AC Volts DC Resistance (Ohms) Diode Test Rugged ABS case with rubber boot Fits naturally in your hand despite classic design Auto power-off (APO) to conserve battery life Competitive Advantages: The testing capability packed into this classic style meter is its main competitive advantage. In addition to all of the ranges, it has direct temperature measurement and it works with all of Fieldpiece's accessory head instruments to make it one of the most complete classic style meters available for HVAC/R. Add to that the fact that the classic design still fits naturally in your hand and comes standard with a rugged rubber boot. Additional Specifications: DC voltage Ranges: 200mV, 2000mV, 20V, 200V, 600V Resolution: 0.1mV Accuracy: 0.5%±1 Input impedence: 10 milliohm AC voltage (50Hz-500Hz) Ranges: 200mV, 2000mV, 20V, 200V, 600V Resolution: 0.1mV Accuracy: 1.2%±4(200mV to 20V ranges), 2%±4(200V, 600V ranges) Input impedence: 10 milliohm DC Current (through meter) Ranges: 200 micro A, 20mA, 200mA Resolution: 0.1 micro A Accuracy: 1.0%±1 Voltage burden: 800mV AC Current (through meter) Ranges: 200 micro A, 20mA, 200mA Resolution: 0.1 micro A Accuracy: 1.5%±4 Voltage burden: 800mV Frequency (autoranging) Range: 10Hz to 40KHz Resolution: 1Hz Sensitivity: 3.5V rms min Accuracy: 0.1%± 3 Resistance (ohms) Ranges: 200 ohms, 2 k ohms, 200k ohms, 20M ohms Resolution: 0.1 ohm Accuracy: 1.0%±4 (200 ohm to 200k ohm ranges), 2.0%±4 (20M ohm range) Open circuit voltage: 0.3VDC typical, (3.0VDC on 200 ohm) Diode test Accuracy: 1.5%±3 Test current: Approx. 1.0mA Open circuit voltage: 3.0VDC typical Capacitance (MFD) Ranges: 200 micro F, 2k micro F, 20k micro F Resolution: 0.1 micro F Accuracy: 4%±10 Test frequency: 21Hz Test voltage: Temperature Ranges: -30 to 1400°F (-34 to 750°C) Resolution: 0.1°F/°C Accuracy: ±1°F; 32 to 120°F (±0.5°C; 0 to 48°C), ±1.0%+1.5°F; -4 to 750°F (±1.0%+1.0°C; -20 to 399°C) ±3.0%+4°F; -30 to -4°F and 750 to 1400°F (±3.0%+2°C; -34 to -20°C and 399 to 750°C) Sensor type: K-type thermocouple Field Calibration (temp offset pot) The LT17A can be easily calibrated on the job. Use a bucket of ice water to have a known 32°F (0°C) temperature. With the thermocouple in the ice water, adjust the TEMP OFFSET pot on the face of the meter until it reads 32.0 (0.0). Fuse Replacement: When only certain ranges quit working, check the fuse. Open the case and replace according to the Overload Protection values below. If that doesn't work visit our Warranty Page to check for other problems.

Hubzone SKU LT17A
Manufacturer Fieldpiece
Manufacturer Part Number LT17A
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

What's Included: Classic Style Clamp Meter with Temperature - LT17A Deluxe Silicone Test Leads - ADLS2 Short Alligator Lead Extensions - ASA2 400A Amp Clamp Accessory - ACH4 Wrap Tab Bead Tip Thermocouple - ATB1 Mail Pouch-Style Instrument Case - ANC5 9V battery (installed) Operator's manual Overview: The LT17A is a manual ranger that covers most of the parameters and ranges you need for most HVAC/R applications. The LT17A meter measures current, resistance, voltage, capacitance, frequency, continuity, and temperature. Test leads store in the meter body and, with the probe tips removed, connect the LT17A to Fieldpiece accessory heads. The body is made out of durable ABS plastic and comes with a bright blue backlight for poorly lit test areas. Get great accuracy using the included k-type thermocouple and an easily accessible temperature calibration pot. The LT17A is a manual ranging DMM that comes with an amp clamp and k-type thermocouple. Use the MIN/MAX function to record highs and lows. The continuity beeper tells you if a circuit is open or closed. Operation of the LT17A is easy. Simply select a range and test. Features and Benefits: Works with Fieldpiece Accessory Heads There is a Fieldpiece accessory head available for just about any job. There are heads to measure temperature, superheat, subcooling, RH%, wet bulb, dew point, vacuum (microns of mercury), manometer (inches of water column), amps AC&DC, high voltage, CO, %CO2, air velocity, and many more. Continuity Indicator If you were doing lab testing, these features would probably drive you crazy. We've heard from more than one HVAC/R veteran that these features really remind you of what you're doing and they've avoided potentially dangerous situations in the field. The Hi-V LED and beeper let you know when you've hooked up to a circuit over 30V. The continuity LED and beeper tells you if a circuit is open or closed. 400AAC Using the detachable test leads and the accessory head amp clamp, read 0-400 amps directly on your meter. Capacitance (MFD) Measure microfarads on motor-run and motor-start capacitors using this range. Disconnect the capacitor from power first. Short the terminals to discharge the capacitor. Disconnect any resistors that might be between the terminals of the capacitor and measure to check for degradation. Microamps DC - Flame Rectification Tests The most common "no heat" call has to do with a malfunctioning flame sensing diode. Simply turn the meter to microamps DC, hook up, and see if the flame sensing rod is functioning properly. Frequency Measure from 10Hz to 40kHz using this range with 1 Hz resolution Silicone Leads with Detachable Probe Tips Because the wire insulation is silicone, the leads stay flexible in cold weather and will not melt if bumped by a soldering iron. When testing electrical circuits with two hands, there is a risk that a careless mistake may complete a circuit through your body and potentially cause death or injury. Use the either probe clip on rubber boot to connect and firmly hold the V lead in place, detach the COM probe tip, connect an alligator lead tip to COM and ground, and perform a one-hand test more easily than most meters on the market. Built-in lead storage makes it easy to keep everything together from job to job. Tilt Stand and Magnetic Hanger Technicians enjoy the magnetic hanger because it keeps the meter out of the way while testing. The LT17A includes the magnet and a tilt stand to give you a choice in the way you want to use it. Bright Blue Backlight Easily read the display in overcast conditions or in dimly lit areas. MAX/MIN hold Record the minimum or maximum reading during a measurement. To exit the MIN/MAX function, hold the button for more than 2 seconds More Features: Volts AC Volts DC Resistance (Ohms) Diode Test Rugged ABS case with rubber boot Fits naturally in your hand despite classic design Auto power-off (APO) to conserve battery life Competitive Advantages: The testing capability packed into this classic style meter is its main competitive advantage. In addition to all of the ranges, it has direct temperature measurement and it works with all of Fieldpiece's accessory head instruments to make it one of the most complete classic style meters available for HVAC/R. Add to that the fact that the classic design still fits naturally in your hand and comes standard with a rugged rubber boot. Additional Specifications: DC voltage Ranges: 200mV, 2000mV, 20V, 200V, 600V Resolution: 0.1mV Accuracy: 0.5%±1 Input impedence: 10 milliohm AC voltage (50Hz-500Hz) Ranges: 200mV, 2000mV, 20V, 200V, 600V Resolution: 0.1mV Accuracy: 1.2%±4(200mV to 20V ranges), 2%±4(200V, 600V ranges) Input impedence: 10 milliohm DC Current (through meter) Ranges: 200 micro A, 20mA, 200mA Resolution: 0.1 micro A Accuracy: 1.0%±1 Voltage burden: 800mV AC Current (through meter) Ranges: 200 micro A, 20mA, 200mA Resolution: 0.1 micro A Accuracy: 1.5%±4 Voltage burden: 800mV Frequency (autoranging) Range: 10Hz to 40KHz Resolution: 1Hz Sensitivity: 3.5V rms min Accuracy: 0.1%± 3 Resistance (ohms) Ranges: 200 ohms, 2 k ohms, 200k ohms, 20M ohms Resolution: 0.1 ohm Accuracy: 1.0%±4 (200 ohm to 200k ohm ranges), 2.0%±4 (20M ohm range) Open circuit voltage: 0.3VDC typical, (3.0VDC on 200 ohm) Diode test Accuracy: 1.5%±3 Test current: Approx. 1.0mA Open circuit voltage: 3.0VDC typical Capacitance (MFD) Ranges: 200 micro F, 2k micro F, 20k micro F Resolution: 0.1 micro F Accuracy: 4%±10 Test frequency: 21Hz Test voltage: Temperature Ranges: -30 to 1400°F (-34 to 750°C) Resolution: 0.1°F/°C Accuracy: ±1°F; 32 to 120°F (±0.5°C; 0 to 48°C), ±1.0%+1.5°F; -4 to 750°F (±1.0%+1.0°C; -20 to 399°C) ±3.0%+4°F; -30 to -4°F and 750 to 1400°F (±3.0%+2°C; -34 to -20°C and 399 to 750°C) Sensor type: K-type thermocouple Field Calibration (temp offset pot) The LT17A can be easily calibrated on the job. Use a bucket of ice water to have a known 32°F (0°C) temperature. With the thermocouple in the ice water, adjust the TEMP OFFSET pot on the face of the meter until it reads 32.0 (0.0). Fuse Replacement: When only certain ranges quit working, check the fuse. Open the case and replace according to the Overload Protection values below. If that doesn't work visit our Warranty Page to check for other problems.

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents