High Limit Triple Vertical Mount Aquastat Relay, High = 10-Degree(F) Diff, Low = 10-25-Degree(F) Adj Differential, L8124E1016
Description:Triple Aquastat Relay with High limit : 10F fixed. low limit: 10-25F adj. Differential Application:Triple Aquastat Relay with High limit Operating Range, Low Limit (F): 110F to 220FOperating Range, Low Limit (C): 43C to 104C Operating Range, High Limit (F): 130F to 240F Operating Range, High Limit (C): 54C to 116C Differential Temperature (F): High limit : 10F fixed. low limit: 10-25F adj. Switching Action: SPST: High & Low LimitMaximum Operating Pressure (psi): 200 psi on outside of immersion well, 100 psi on capsule if inserted directly.Maximum Operating Pressure (kPa): 1378 kPa on outside of immersion well, 690 kPa on capsule if inserted directly.Electrical Ratings (burner AFL) Line Voltage: 7.4 A @ 120 Vac. 3.7 A @ 240 Vac Electrical Ratings (burner ALR) Line Voltage: 44.4 A @ 120 Vac. 22.7 A @ 240 Vac Electrical Ratings (circulator AFL): 7.4 A @ 120 Vac. 3.7 A @ 240 Vac Electrical Ratings (circulator ALR): 44.4 A @ 120 Vac. 22.7 A @ 240 Vac Voltage: 120 Vac Frequency: 60 Hz Dimensions (in.): 6 1/8 in. high x 4 3/8 in. wide x 3 1/16 in. deep Dimensions (mm): 156 mm high x 111 mm wide x 78 mm deep Mounting: Vertical Mounting Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Maximum Ambient Temperature (F): 150F at switches, 265F at sensing element. Maximum Ambient Temperature (C): 66C at switches, 129C at sensing element. Minimum Ambient Temperature (F): -30F Minimum Ambient Temperature (C): -9C Electrical Connections: Quick-Connect / Screw Ref: Honeywell.com
Your Price
Contract Pricing
Product Overview
Description:Triple Aquastat Relay with High limit : 10F fixed. low limit: 10-25F adj. Differential Application:Triple Aquastat Relay with High limit Operating Range, Low Limit (F): 110F to 220FOperating Range, Low Limit (C): 43C to 104C Operating Range, High Limit (F): 130F to 240F Operating Range, High Limit (C): 54C to 116C Differential Temperature (F): High limit : 10F fixed. low limit: 10-25F adj. Switching Action: SPST: High & Low LimitMaximum Operating Pressure (psi): 200 psi on outside of immersion well, 100 psi on capsule if inserted directly.Maximum Operating Pressure (kPa): 1378 kPa on outside of immersion well, 690 kPa on capsule if inserted directly.Electrical Ratings (burner AFL) Line Voltage: 7.4 A @ 120 Vac. 3.7 A @ 240 Vac Electrical Ratings (burner ALR) Line Voltage: 44.4 A @ 120 Vac. 22.7 A @ 240 Vac Electrical Ratings (circulator AFL): 7.4 A @ 120 Vac. 3.7 A @ 240 Vac Electrical Ratings (circulator ALR): 44.4 A @ 120 Vac. 22.7 A @ 240 Vac Voltage: 120 Vac Frequency: 60 Hz Dimensions (in.): 6 1/8 in. high x 4 3/8 in. wide x 3 1/16 in. deep Dimensions (mm): 156 mm high x 111 mm wide x 78 mm deep Mounting: Vertical Mounting Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Maximum Ambient Temperature (F): 150F at switches, 265F at sensing element. Maximum Ambient Temperature (C): 66C at switches, 129C at sensing element. Minimum Ambient Temperature (F): -30F Minimum Ambient Temperature (C): -9C Electrical Connections: Quick-Connect / Screw Ref: Honeywell.com