Product Details

Review product information, specifications, and procurement details.

Intermittant Pilot Ignition Control (Replaces Reznor 257010)
● In Stock

Intermittant Pilot Ignition Control (Replaces Reznor 257010)

*Intermittent pilot gas ignition control module*For use with intermittent pilot boilers, furnaces and other heating appliances*Microprocessor-based*Monitors timing, trial for ignition, flame sensing and lockout* Remote flame sensing*2 minute trial for ignition*60 minute lock out if pilot flame is not sensed in 2 minutes* Compatible with LP or natural gas* Damper control input Features Intermittent pilot gas ignition control module For use with intermittent pilot boilers, furnaces and other heating appliances Microprocessor-based Monitors timing, trial for ignition, flame sensing and lockout Remote flame sensing 2 minute trial for ignition 60 minute lock out if pilot flame is not sensed in 2 minutes Compatible with LP or natural gas Damper control input Specifications Control Voltage: 18-30 VAC Frequency: 50/60 Hz Humidity: 5%-95% R.H. (non-condensing) at +55°C Operating Temperature: -40°F to 165°F, -40°C to 75°C Pilot Valve: 2A @ 24 VAC Main Gas Valve: 2A @ 24 VAC Current Draw: 100 mA maximum Pre-Purge Delay: 0 seconds Trial for ignition: 2 minutes Lock Out Time: 60 minutes

Hubzone SKU ICM2905
Manufacturer ICM Controls
Manufacturer Part Number ICM2905
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

*Intermittent pilot gas ignition control module*For use with intermittent pilot boilers, furnaces and other heating appliances*Microprocessor-based*Monitors timing, trial for ignition, flame sensing and lockout* Remote flame sensing*2 minute trial for ignition*60 minute lock out if pilot flame is not sensed in 2 minutes* Compatible with LP or natural gas* Damper control input Features Intermittent pilot gas ignition control module For use with intermittent pilot boilers, furnaces and other heating appliances Microprocessor-based Monitors timing, trial for ignition, flame sensing and lockout Remote flame sensing 2 minute trial for ignition 60 minute lock out if pilot flame is not sensed in 2 minutes Compatible with LP or natural gas Damper control input Specifications Control Voltage: 18-30 VAC Frequency: 50/60 Hz Humidity: 5%-95% R.H. (non-condensing) at +55°C Operating Temperature: -40°F to 165°F, -40°C to 75°C Pilot Valve: 2A @ 24 VAC Main Gas Valve: 2A @ 24 VAC Current Draw: 100 mA maximum Pre-Purge Delay: 0 seconds Trial for ignition: 2 minutes Lock Out Time: 60 minutes

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents