Product Details

Review product information, specifications, and procurement details.

ICM401 Phase Loss and Reversal Protection, 190-600 VAC
● In Stock

ICM401 Phase Loss and Reversal Protection, 190-600 VAC

Features Low cost 3 phase protection for single side Monitors for phase reversal, phase loss, unbalance % as a function of input voltage Bright LED indicators for ON and FAULT Universal 3 phase input: 190-600 VAC Highly reliable passive electronics Easy to install, no adjustments Less than 1-second phase loss response Automatic reset from a fault condition Compact packaging: fits almost anywhere Epoxy coated for added protection Works great with the ICM450 for load side monitoring of part winding start motors and multiple compressor systems For open board model, order ICM403 Mode of Operation:If all 3 phases are relatively equal and in proper sequence, the normally open contacts (Y/Y-OUT) will close when 24 volts is applied between C and Y terminals. If the phases are out of sequence, or if one is missing, the contacts will never close. If a phase is lost while the ICM401 is energized, the contacts will open immediately and will remain open until the error is corrected. An illuminated green LED indicates the output is energized, and an illuminated red LED indicates there is a fault and the output is de-energized.

Hubzone SKU ICM401A
Manufacturer ICM Controls
Manufacturer Part Number ICM401A
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

Features Low cost 3 phase protection for single side Monitors for phase reversal, phase loss, unbalance % as a function of input voltage Bright LED indicators for ON and FAULT Universal 3 phase input: 190-600 VAC Highly reliable passive electronics Easy to install, no adjustments Less than 1-second phase loss response Automatic reset from a fault condition Compact packaging: fits almost anywhere Epoxy coated for added protection Works great with the ICM450 for load side monitoring of part winding start motors and multiple compressor systems For open board model, order ICM403 Mode of Operation:If all 3 phases are relatively equal and in proper sequence, the normally open contacts (Y/Y-OUT) will close when 24 volts is applied between C and Y terminals. If the phases are out of sequence, or if one is missing, the contacts will never close. If a phase is lost while the ICM401 is energized, the contacts will open immediately and will remain open until the error is corrected. An illuminated green LED indicates the output is energized, and an illuminated red LED indicates there is a fault and the output is de-energized.

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents