Product Details

Review product information, specifications, and procurement details.

Inducer Motor, 3000 RPM, HC21ZS123
● In Stock

Inducer Motor, 3000 RPM, HC21ZS123

Carrier HC21ZS123 Inducer Motor (3000 RPM) An OEM replacement draft inducer motor for Carrier HVAC equipment, used to replace a failed inducer motor in compatible systems where part number HC21ZS123 is specified. Key Features: * Official OEM inducer motor for Carrier HVAC equipment * Electrical rating: 115V * Speed: 3000 RPM * Listed as replacing: HC21ZE123A and HC21ZE123 Compatibility & Applications: * Listed for Carrier HVAC equipment (model-specific compatibility is not provided on the listing) * Must only be used where the manufacturer specifies this exact part number: HC21ZS123 * Product Q&A note: for a broken inducer motor identified as Jakel J238-112-11202 / 1183526, SupplyHouse staff stated HC21ZS123 is not the direct replacement and identified a different part number as the direct replacement for that motor Installation & Operation Notes: * Installation should be performed by a qualified HVAC service technician * Refer to the unit's service/installation manual and wiring diagram for the correct model to confirm: * Correct part selection by model/serial * Proper wiring and motor orientation * Fastener requirements and gasket/seal placement * Review-reported installation notes: * One reviewer noted the screw holes are not threaded and had to source self-drilling screws locally * One reviewer advises cleaning off the old crumbled foam gasket material during reassembly and replacing the seal as needed (reviewer guidance, not manufacturer instructions) Maintenance & Troubleshooting: * Review-reported reasons for replacement include: * A loud/noisy inducer motor, with replacement described as restoring quieter operation * A manufacturing/connection defect (one reviewer reported a "cold solder joint" on a terminal and re-soldered it before use) * If issues persist after replacement, use the equipment's diagnostic procedures in the service manual to confirm the inducer assembly, controls, and safeties are operating correctly (no additional diagnostic steps are provided on the product listing) User Reviews & Q&A Summary: * Reviews commonly describe: * Direct-fit replacement and straightforward install * Quieter operation after replacement * Cost savings versus replacing the entire inducer assembly * Mixed feedback includes: * A reported quality-control issue at a terminal connection (reviewer-reported and corrected by the customer) * Hardware/assembly frustration (reviewer-reported unthreaded screw holes requiring separate screws) * Q&A theme: * Fit/compatibility depends on the exact existing motor/part number; SupplyHouse staff advised a different replacement part number for a specific Jakel/Carrier-referenced motor number, reinforcing the need to match by unit model/serial or confirmed part cross-reference

Hubzone SKU HC21ZS123
Manufacturer Carrier
Manufacturer Part Number HC21ZS123
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

Carrier HC21ZS123 Inducer Motor (3000 RPM) An OEM replacement draft inducer motor for Carrier HVAC equipment, used to replace a failed inducer motor in compatible systems where part number HC21ZS123 is specified. Key Features: * Official OEM inducer motor for Carrier HVAC equipment * Electrical rating: 115V * Speed: 3000 RPM * Listed as replacing: HC21ZE123A and HC21ZE123 Compatibility & Applications: * Listed for Carrier HVAC equipment (model-specific compatibility is not provided on the listing) * Must only be used where the manufacturer specifies this exact part number: HC21ZS123 * Product Q&A note: for a broken inducer motor identified as Jakel J238-112-11202 / 1183526, SupplyHouse staff stated HC21ZS123 is not the direct replacement and identified a different part number as the direct replacement for that motor Installation & Operation Notes: * Installation should be performed by a qualified HVAC service technician * Refer to the unit's service/installation manual and wiring diagram for the correct model to confirm: * Correct part selection by model/serial * Proper wiring and motor orientation * Fastener requirements and gasket/seal placement * Review-reported installation notes: * One reviewer noted the screw holes are not threaded and had to source self-drilling screws locally * One reviewer advises cleaning off the old crumbled foam gasket material during reassembly and replacing the seal as needed (reviewer guidance, not manufacturer instructions) Maintenance & Troubleshooting: * Review-reported reasons for replacement include: * A loud/noisy inducer motor, with replacement described as restoring quieter operation * A manufacturing/connection defect (one reviewer reported a "cold solder joint" on a terminal and re-soldered it before use) * If issues persist after replacement, use the equipment's diagnostic procedures in the service manual to confirm the inducer assembly, controls, and safeties are operating correctly (no additional diagnostic steps are provided on the product listing) User Reviews & Q&A Summary: * Reviews commonly describe: * Direct-fit replacement and straightforward install * Quieter operation after replacement * Cost savings versus replacing the entire inducer assembly * Mixed feedback includes: * A reported quality-control issue at a terminal connection (reviewer-reported and corrected by the customer) * Hardware/assembly frustration (reviewer-reported unthreaded screw holes requiring separate screws) * Q&A theme: * Fit/compatibility depends on the exact existing motor/part number; SupplyHouse staff advised a different replacement part number for a specific Jakel/Carrier-referenced motor number, reinforcing the need to match by unit model/serial or confirmed part cross-reference

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents