Product Details

Review product information, specifications, and procurement details.

305V Zone Valve Control - 5 Zones w/ Priority
● In Stock

305V Zone Valve Control - 5 Zones w/ Priority

The Zone Valve Control 305V connects up to five thermostats and operates zone valves to provide heating to a zoned hydronic heating system. The 305V operates a system pump whenever a zone valve opens. Zone 1 can operate either a zone valve or a circulator to provide heat to an indirect domestic hot water tank with optional priority over zones 2 through 5. The 305V includes optional exercising to prevent circulator seizure when not in use, and optional post purge operation of the domestic hot water tank to maximize energy savings. The 305V provides a RoomResponse™ signal to modulating-condensing boilers to optimize comfort while improving boiler efficiency. Features Away signal shared between tekmar thermostats CSA approved Compatible with 2, 3 and 4-wire zone valves Compatible with all low voltage thermostats Four ground screws Fuses protect transformers and pumps LED for each zone, priority, end switch and RoomResponseTM Post purge Priority override Pump exercising RoomResponseTM signal Top, bottom and back conduit knockouts Two spare fuses included Unlimited zone expansion Zone priority Specifications Enclosure - Cover: ABS plastic, Base: galvanized steel, NEMA type 1 Approvals - CSA C US Ambient conditions - Indoor use only, 32 to 122°F (0 to 50°C), RH 90% non-condensing Power supply - 115 V (ac) ±10%, 60 Hz, 11 A Transformer - 80 VA at 24 V (ac) Control load - 7 VA at 24 V (ac) Fuses - T5A 250 V slow blow 5 x 20 mm glass fuse, two spare fuses included Zone valve outputs - 24 V (ac), 2 A max per output Zone valve end switch - 24 V (ac) Pump relays - 230 V (ac), 5 A, 1/3 hp Boiler XX end switch - 24 V (ac), 5 A DHW end switch - 24 V (ac), 5 A Mod boiler output - 0-10 V (dc) 500 ohm min load impedance / 4-20 mA 1 k ohm max load impedance

Hubzone SKU 305V
Manufacturer Tekmar
Manufacturer Part Number 305V
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

The Zone Valve Control 305V connects up to five thermostats and operates zone valves to provide heating to a zoned hydronic heating system. The 305V operates a system pump whenever a zone valve opens. Zone 1 can operate either a zone valve or a circulator to provide heat to an indirect domestic hot water tank with optional priority over zones 2 through 5. The 305V includes optional exercising to prevent circulator seizure when not in use, and optional post purge operation of the domestic hot water tank to maximize energy savings. The 305V provides a RoomResponse™ signal to modulating-condensing boilers to optimize comfort while improving boiler efficiency. Features Away signal shared between tekmar thermostats CSA approved Compatible with 2, 3 and 4-wire zone valves Compatible with all low voltage thermostats Four ground screws Fuses protect transformers and pumps LED for each zone, priority, end switch and RoomResponseTM Post purge Priority override Pump exercising RoomResponseTM signal Top, bottom and back conduit knockouts Two spare fuses included Unlimited zone expansion Zone priority Specifications Enclosure - Cover: ABS plastic, Base: galvanized steel, NEMA type 1 Approvals - CSA C US Ambient conditions - Indoor use only, 32 to 122°F (0 to 50°C), RH 90% non-condensing Power supply - 115 V (ac) ±10%, 60 Hz, 11 A Transformer - 80 VA at 24 V (ac) Control load - 7 VA at 24 V (ac) Fuses - T5A 250 V slow blow 5 x 20 mm glass fuse, two spare fuses included Zone valve outputs - 24 V (ac), 2 A max per output Zone valve end switch - 24 V (ac) Pump relays - 230 V (ac), 5 A, 1/3 hp Boiler XX end switch - 24 V (ac), 5 A DHW end switch - 24 V (ac), 5 A Mod boiler output - 0-10 V (dc) 500 ohm min load impedance / 4-20 mA 1 k ohm max load impedance

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents