550,000-1,100,000 BTU 301GAS Multi-Fit Burner w/ 14" Air Tube, "C" Diffuser
550,000-1,100,000 BTU 301GAS Multi-Fit Burner w/ 14" Air Tube, "C" Diffuser Product Features Converts from propane to natural gas with just an orifice change. No conversion kit needed! Factory-packaged with combustion control and gas train (assembled, shipped loose; also available as knockdown. Shipped completely pre-wired for easy installation and startup. Knockdown version also available. Does not require a refractory liner. Fires with or without a combustion chamber. Swing-away housing design Product Specifications 550,000-1,100,000 Btuh Fuels: Natural Gas or Propane Gas Maximum Supply Pressure: 14 inches w.c. Minimum Supply Pressure: 5.0 inches w.c. Manifold Pressure: 3.5 inches w.c. Carlin 60200FR Microprocessor Control 4 sec. Trial for Ignition (TFI) 1.3 Sec. FFRT Pre-purge and post-purge Serviceman Reset Protection Latch-up after three consecutive lockouts Interrupted Duty Ignition Recycle on Flame Failure Power: 120 vac, 60Hz, 1-Phase Current: Approximately 2.5 Amps Limit Circuit Input: 120 vac, 60 Hz Motor: 1/6 HP, 3450 RPM, 60 Hz Fuel Valve Power: 120 vac, 60 Hz Ignition: Carlin Model 41800 Solid State Electronic Ignition Ignition Voltage: 9,000 volts
Your Price
Contract Pricing
Product Overview
550,000-1,100,000 BTU 301GAS Multi-Fit Burner w/ 14" Air Tube, "C" Diffuser Product Features Converts from propane to natural gas with just an orifice change. No conversion kit needed! Factory-packaged with combustion control and gas train (assembled, shipped loose; also available as knockdown. Shipped completely pre-wired for easy installation and startup. Knockdown version also available. Does not require a refractory liner. Fires with or without a combustion chamber. Swing-away housing design Product Specifications 550,000-1,100,000 Btuh Fuels: Natural Gas or Propane Gas Maximum Supply Pressure: 14 inches w.c. Minimum Supply Pressure: 5.0 inches w.c. Manifold Pressure: 3.5 inches w.c. Carlin 60200FR Microprocessor Control 4 sec. Trial for Ignition (TFI) 1.3 Sec. FFRT Pre-purge and post-purge Serviceman Reset Protection Latch-up after three consecutive lockouts Interrupted Duty Ignition Recycle on Flame Failure Power: 120 vac, 60Hz, 1-Phase Current: Approximately 2.5 Amps Limit Circuit Input: 120 vac, 60 Hz Motor: 1/6 HP, 3450 RPM, 60 Hz Fuel Valve Power: 120 vac, 60 Hz Ignition: Carlin Model 41800 Solid State Electronic Ignition Ignition Voltage: 9,000 volts