Product Details

Review product information, specifications, and procurement details.

150,000-275,000 BTU EZ Gas Pro Multi-Fit Burner w/ 16" Air Tube, "A" Diffuser
● In Stock

150,000-275,000 BTU EZ Gas Pro Multi-Fit Burner w/ 16" Air Tube, "A" Diffuser

Overview: The EZGas Pro burner converts existing oil-fired boilers, furnaces, and water heaters to natural gas or propane at a fraction of the cost of replacing the appliance. This natural gas converter comes factory packed with combustion control and gas fuel train. Unlike other conversion burners, it does not require a refractory liner – fires with or without a combustion chamber. Proven in extensive boiler and furnace testing, these gas conversion burners will meet your needs for residential gas burning applications. If you have any questions about this or any other oil to gas conversion burner, please contact us at your convenience. Specifications: 150,000 to 275,000 Btuh Fuels: Natural Gas or Propane Gas Maximum Supply Pressure: 14 inches w.c. Minimum Supply Pressure: 5.0 inches w.c. Manifold Pressure: 3.5 inches w.c. Carlin 60200FR Microprocessor Control 4 sec. Trial for Ignition (TFI) 1.3 Sec. FFRT Pre-purge and post-purge Serviceman Reset Protection Latch-up after three consecutive lockouts Interrupted Duty Ignition Recyle on Flame Failure Power: 120 vac, 60Hz, 1-Phase Current: Approximately 2.0 Amps Limit Circuit Input: 120 vac, 60 Hz Motor: 1/15 HP, 3450 RPM, 60 Hz Motor Frame: 48 Frame, “M” Flange Fuel Valve Power: 120 vac, 60 Hz Ignition: Carlin Model 41800 Solid State Electronic Ignition Ignition Voltage: 9,000 volts

Hubzone SKU 9859216AFR
Manufacturer Carlin Combustion
Manufacturer Part Number 9859216AFR
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

Overview: The EZGas Pro burner converts existing oil-fired boilers, furnaces, and water heaters to natural gas or propane at a fraction of the cost of replacing the appliance. This natural gas converter comes factory packed with combustion control and gas fuel train. Unlike other conversion burners, it does not require a refractory liner – fires with or without a combustion chamber. Proven in extensive boiler and furnace testing, these gas conversion burners will meet your needs for residential gas burning applications. If you have any questions about this or any other oil to gas conversion burner, please contact us at your convenience. Specifications: 150,000 to 275,000 Btuh Fuels: Natural Gas or Propane Gas Maximum Supply Pressure: 14 inches w.c. Minimum Supply Pressure: 5.0 inches w.c. Manifold Pressure: 3.5 inches w.c. Carlin 60200FR Microprocessor Control 4 sec. Trial for Ignition (TFI) 1.3 Sec. FFRT Pre-purge and post-purge Serviceman Reset Protection Latch-up after three consecutive lockouts Interrupted Duty Ignition Recyle on Flame Failure Power: 120 vac, 60Hz, 1-Phase Current: Approximately 2.0 Amps Limit Circuit Input: 120 vac, 60 Hz Motor: 1/15 HP, 3450 RPM, 60 Hz Motor Frame: 48 Frame, “M” Flange Fuel Valve Power: 120 vac, 60 Hz Ignition: Carlin Model 41800 Solid State Electronic Ignition Ignition Voltage: 9,000 volts

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents