Product Details

Review product information, specifications, and procurement details.

Genesis Primary Control, Lockout Time 15 Seconds, 12VDC
● In Stock

Genesis Primary Control, Lockout Time 15 Seconds, 12VDC

The Beckett GeniSys™ 12V Advanced Burner Control is a 12 Vdc primary safety control for oil burners used on pressure washers, road stripers, crack sealers, hot patchers, and asphalt distributors, to name a few examples. The GeniSys 12V is used with a suitable cad cell fl ame sensor to control the oil burner motor, igniter, and optional solenoid valve. It can provide interrupted or intermittent duty ignition, and it has a 15-second lockout time. Features & Benefits: *New Feature* Programmable valve-on delay and motor-off delay provides chamber cooling after call for heat Valve-on delay / motor-off delay (Field programmable with Beckett’s Contractor Tool) Epoxy potted for moisture resistance Welded relay protection with redundant motor relays High ambient temperature rating Alarm output enables visual or audio indication of flame failure and lock out condition Interrupted ignition Relight function Fused protection 15 second lockout time Communication port Inputs Voltage: 12 VDC nominal (11 to 16 VDC) Current: 160 mA nominal (500 mA max at 16 VDC) Enable Load: 40mA at 12 VDC Outputs Motor: 12 VDC, 20 full load amps (FLA), 100 locked rotor amps (LRA) Igniter: 12 VDC, 5 A Solenoid Valve: 12 VDC, 2 A Lockout Alarm: 12 VDC, 2 A Programed Delays (Changeable with Beckett Contractor Tool) Valve On Delay: 15 seconds Motor Off Delay: 2 minutes

Hubzone SKU 7556P152MU
Manufacturer R.W. Beckett
Manufacturer Part Number 7556P152MU
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

The Beckett GeniSys™ 12V Advanced Burner Control is a 12 Vdc primary safety control for oil burners used on pressure washers, road stripers, crack sealers, hot patchers, and asphalt distributors, to name a few examples. The GeniSys 12V is used with a suitable cad cell fl ame sensor to control the oil burner motor, igniter, and optional solenoid valve. It can provide interrupted or intermittent duty ignition, and it has a 15-second lockout time. Features & Benefits: *New Feature* Programmable valve-on delay and motor-off delay provides chamber cooling after call for heat Valve-on delay / motor-off delay (Field programmable with Beckett’s Contractor Tool) Epoxy potted for moisture resistance Welded relay protection with redundant motor relays High ambient temperature rating Alarm output enables visual or audio indication of flame failure and lock out condition Interrupted ignition Relight function Fused protection 15 second lockout time Communication port Inputs Voltage: 12 VDC nominal (11 to 16 VDC) Current: 160 mA nominal (500 mA max at 16 VDC) Enable Load: 40mA at 12 VDC Outputs Motor: 12 VDC, 20 full load amps (FLA), 100 locked rotor amps (LRA) Igniter: 12 VDC, 5 A Solenoid Valve: 12 VDC, 2 A Lockout Alarm: 12 VDC, 2 A Programed Delays (Changeable with Beckett Contractor Tool) Valve On Delay: 15 seconds Motor Off Delay: 2 minutes

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents