Product Details

Review product information, specifications, and procurement details.

Safgard 400 Non-Cycling Steam Primary Low Water Cutoff  - 24V
● In Stock

Safgard 400 Non-Cycling Steam Primary Low Water Cutoff - 24V

Reliable Electronic Operation Easy to Install Low Maintenance; No Blowdowns No Moving Parts to Wear or Stick Time Delay Prevents Burner Short Cycling Inexpensive to Own and Operate 15 Second Burner Off Delay 30 Second Burner On Delay Automatic Reset Low Water Indicating Light Direct Boiler Mounting Eliminates Blowdowns Operation: Burner circuit contacts open after 15 second delay in a low water condition. Delay prevents short cycling caused by momentary fluctuations in the boiler water level. Automatically reactivates burner circuit 30 seconds after water reaches the probe, allowing optional water feeder to raise water level above the probe. Hydrolevel low water cut-offs are electrically operated. A probe is installed in the boiler shell or external manifold and is connected to the control unit. Water is used as a conductor to complete the circuit between the probe and the boiler shell. When water is in contact with the probe, the circuit is completed; when the water level drops below the probe, the circuit opens. Hydrolevel controls provide contacts to de-energize the burner circuit in a low water condition.

Hubzone SKU 45-400-HYDROLEVEL
Manufacturer Hydrolevel
Manufacturer Part Number 45-400-HYDROLEVEL
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

Reliable Electronic Operation Easy to Install Low Maintenance; No Blowdowns No Moving Parts to Wear or Stick Time Delay Prevents Burner Short Cycling Inexpensive to Own and Operate 15 Second Burner Off Delay 30 Second Burner On Delay Automatic Reset Low Water Indicating Light Direct Boiler Mounting Eliminates Blowdowns Operation: Burner circuit contacts open after 15 second delay in a low water condition. Delay prevents short cycling caused by momentary fluctuations in the boiler water level. Automatically reactivates burner circuit 30 seconds after water reaches the probe, allowing optional water feeder to raise water level above the probe. Hydrolevel low water cut-offs are electrically operated. A probe is installed in the boiler shell or external manifold and is connected to the control unit. Water is used as a conductor to complete the circuit between the probe and the boiler shell. When water is in contact with the probe, the circuit is completed; when the water level drops below the probe, the circuit opens. Hydrolevel controls provide contacts to de-energize the burner circuit in a low water condition.

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents