Product Details

Review product information, specifications, and procurement details.

tN2 House Control
● In Stock

tN2 House Control

Overview: The House Control 400 is designed to operate as part of a complete hydronic heating system with tekmarNet®2 (tN2) thermostats. It can provide operation of one outdoor reset water temperature in addition to Domestic Hot Water and Setpoint capabilities. It has four built in zones that can operate up to four zone pumps. It is easy to add more zones, add schedules or other convenient accessories through the use of the tekmarNet®4 (tN4) Expansion terminals. Features: Enclosure: O-Enclosure, blue PC+ABS UL94-5VA plastic Approvals: CSA C US, meets ICES & FCC regulations for EMI / RFI Ambient Conditions: Indoor use only, 32 to 104°F (0 to 40°C), RH 90% Non-condensing Power Supply: 24 V (ac) ±10% 60 Hz, 100 VA max, Class 2 Control Load: 2 VA Zone Valve Load: 24 V (ac) 2 A, maximum combined current (zones 1 to 4): 89 VA (3.7A) Boiler Relay: 24 V (ac) 5 A Boiler System Pump Relay - 115 V (ac) 5 A, 1/6 HP DHW Pump Relay: 115 V (ac) 5 A, 1/6 HP Pump Power: 115 V (ac) 12 A max Setpoint and DHW Calls: Short, 0 - 32 V (ac) Boiler Modulating Output: 0 - 10 V (dc), 3 kohm minimum load impedance

Hubzone SKU 400
Manufacturer Tekmar
Manufacturer Part Number 400
UNSPSC Code
40141700 ⓘ
NAICS Code
N/A ⓘ
Unit of Measure N/A
Availability ● In Stock
Lead Time Ships in 1–2 business days
Status ● Active

Your Price

$0.00/ PR

Contract Pricing

Product Overview

Overview: The House Control 400 is designed to operate as part of a complete hydronic heating system with tekmarNet®2 (tN2) thermostats. It can provide operation of one outdoor reset water temperature in addition to Domestic Hot Water and Setpoint capabilities. It has four built in zones that can operate up to four zone pumps. It is easy to add more zones, add schedules or other convenient accessories through the use of the tekmarNet®4 (tN4) Expansion terminals. Features: Enclosure: O-Enclosure, blue PC+ABS UL94-5VA plastic Approvals: CSA C US, meets ICES & FCC regulations for EMI / RFI Ambient Conditions: Indoor use only, 32 to 104°F (0 to 40°C), RH 90% Non-condensing Power Supply: 24 V (ac) ±10% 60 Hz, 100 VA max, Class 2 Control Load: 2 VA Zone Valve Load: 24 V (ac) 2 A, maximum combined current (zones 1 to 4): 89 VA (3.7A) Boiler Relay: 24 V (ac) 5 A Boiler System Pump Relay - 115 V (ac) 5 A, 1/6 HP DHW Pump Relay: 115 V (ac) 5 A, 1/6 HP Pump Power: 115 V (ac) 12 A max Setpoint and DHW Calls: Short, 0 - 32 V (ac) Boiler Modulating Output: 0 - 10 V (dc), 3 kohm minimum load impedance

Full Specifications

Procurement Details

UNSPSC Code 40141700
NAICS Code N/A

Documents